Motor choke CNW M 854

Fully encapsulated three-phase motor choke

Description

Voltage rise (<200V / us) and distortion reduce – protect electrical consumers optimally.

Motor chokes in fully encapsulated version are specially designed for rough environments and offer a very good mechanical protection of the component. The fully encapsulation allows design up to protection ratings IP 66.

Losses and heating are minimized and the leakage current reduced. Longer motor cable lengths are possible. By limiting the rate of voltage rise, the motor insulation is protected and thus prolongs the life. The motor choke also attenuates the conducted interference in lower frequency range very good. The losses and the typical noise in the motor plate can be reduced. Voltage rise (<200V / us) will be reduced.

Increasing the service life of motors, reduction of edge steepness dv/dt to earth and between phases, reduce motor noise, current smoothing.

Unique Selling Point

  • Usable in rough environment
  • Optimal mechanical protection of the choke
  • Different fixings possibilities caused by 3 basic versions
  • Assembly of different options: cables, terminals, terminal box
  • Lower surface temperature
  • Protection class up to IP 66
  • Protection of electrical consumers
  • Limitation of the voltage increase
    to <500V / us
  • Extended service life of electrical consumers
  • Reduction of engine noise
  • Low leakage currents on the motor
  • Longer motor cables possible
  • Easy construction
  • Compact design
  • Production according to UL insulation system E251513 possible

Technical Data

  • Rated voltage: U ≤ 3 x 500 V
  • Reduce the voltage rise dv / dt to <200V / us
  • Field frequency: 0 – 60 Hz
  • Drive switching frequency: up to 150 A >4kHz, from 150 A >1,5KHz
  • According to: EN 60289 / EN 61558
  • Test voltage: L-L 2500 V, AC/50Hz 60s; L-PE 2500 V, AC/50Hz 60s
  • Insulation class: T40/F
  • Protection rating: IP00-IP65
  • Climatic categorie: DIN IEC 60068-1
  • Overload: 1,5 x INenn 1 min / h
  • Ambient temperature: 40 °C
  • Design: standing on foot angle
  • Nominal Voltage : 500 V
  • Rated current : 2 – 37 A
  • Inductance per strand : 0,4 – 7 mH